Accuracy and precision of our method: quantification of androgens
    Testosterone
  Dihydrotestosterone
  Standard, pg   Analysis, pg   SD   Accuracy, %   Precision, %   Analysis, pg   SD   Accuracy, %   Precision, %

  Tissue Interassay                
  15.6   15.7   2.3   0.7   14.8   17.4   2.2   11.8   12.5
  125   125.8   3.0   0.7   2.4   125.7   2.4   0.5   1.9
  1000   1026.9   21.6   2.7   2.1   998.4   13.6   –0.2   1.4
  Tissue Intra-assay                
  15.6   15.8   0.8   1.6   5.0   14.0   1.9   –10.2   13.6
  20   19.0   1.5   –5.2   7.8   16.3   1.1   –18.4   6.8
  62.5   66.3   3.0   6.1   4.5   55.5   0.8   –11.2   1.5
  500   564.8   5.7   13.0   1.0   459.8   9.2   –8.0   2.0
  Plasma Interassay                
  15.6   16.4   1.4   5.4   8.2   16.8   1.6   7.9   9.5
  125   124.8   4.2   –0.2   3.4   122.7   5.0   –1.8   4.1
  1000   1001.7   9.6   0.2   1.0   995.3   22.5   –0.5   2.3
  Plasma Intra-assay                
  15.6   14.3   0.3   –8.3   2.2   16.9   1.1   8.2   6.7
  125   122.1   7.5   –2.3   6.2   126.1   4.1   0.9   3.3
  1000   936.1   20.9   –6.4   2.2   960.5   11.1   –3.9   1.2