Journal of Andrology Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davis, R. O.
Right arrow Articles by Katz, D. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davis, R. O.
Right arrow Articles by Katz, D. F.

Journal of Andrology, Vol 13, Issue 2 139-152, Copyright © 1992 by The American Society of Andrology


REVIEW

New measures of sperm motion. I. Adaptive smoothing and harmonic analysis

R. O. Davis, P. W. Niswander and D. F. Katz
Department of Obstetrics and Gynecology, School of Medicine, University of California, Davis 95616.

Several kinematic measures from computer-aided sperm analysis (CASA) instruments depend critically upon the computation of the spatially averaged path of a sperm's curvilinear swimming trajectory. Presently available instruments compute the average path by smoothing the curvilinear trajectory using a fixed-length running average. We demonstrate that this method significantly distorts the spatially averaged path for irregularly swimming sperm, both within and between trajectories, resulting in inaccurate calculations for the velocity of the average path (VAP), amplitude of lateral head displacement (ALH), beat-cross frequency (BCF), wobble of the curvilinear trajectory (WOB), and straightness of the curvilinear trajectory (STR). The authors introduce an alternative approach, based on engineering signal processing techniques, where the width of the running average is adapted to the changing wavelengths of the major spatial oscillations of each curvilinear trajectory. How this adaptive method results in less distortion of the average path and produces more accurate characterizations of the above measures is shown. This method is implemented in a computer program developed by the authors, called PathTool. It is also demonstrated that the simple methods used to characterize the frequency and amplitude of the major oscillation in a sperm's curvilinear trajectory (ie, BCF and ALH) are only accurate for the most periodic, progressive, and symmetrical trajectories. Three new measures are introduced, based on mathematical harmonic analysis, that are more robust alternatives to the present methods. These new methods and measures are initially evaluated using prototypical sperm trajectories from human semen. Results suggest that adaptive smoothing and harmonic analysis produce more accurate estimates of the frequency and magnitude of oscillations in sperm trajectories than the method based on fixed-length smoothing, BCF, and ALH.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by The American Society of Andrology.